A heating degree day is a measure of how far, and for how long, the outdoor temperature sat below a base temperature. It is the usual way to say whether last winter was harsh, and the usual way to turn a heat-loss rate into a rough yearly total. It is not a property of your house. Two houses in the same town share the degree days and still burn different amounts of fuel.
Look the number up for your town and for the base temperature you are using. A figure from a book written for another city will scale every later calculation by the wrong weather. The bill baseline is the reality check. The heat-loss sketch supplies the rate this page multiplies.
Difficulty
- Level
- Beginner
- Time
- An hour once you have found a local degree-day table
- Skills
- Multiplying a rate by a weather number and not over-trusting the product
Cost estimate
Free
Weather services and public degree-day tables are enough. The calculator on this page runs in the browser.
Materials
| Item | Qty | Notes |
|---|---|---|
| A degree-day total for your town | 1 year | Note the base temperature. 65 degrees F is the common published base in the United States. It is a convention. |
| A heat-loss rate | From the sketch | BTU per hour at a stated temperature difference. |
| The base your thermostat actually suggests | Optional | A tight house with internal gains may track a lower base than 65. |
The definition
For one day, subtract the average outdoor temperature from the base. If the result is negative, that day contributes zero. If the base is 65 degrees F and the average outdoor temperature is 30, that day contributes 35 degree days. Add the days for the heating season, or for a calendar year, and you have the annual heating degree days.
A cold climate can land near 7,000 or more at base 65. A mild coastal climate can land near 2,000 or below. Your town is a lookup, not a guess from this paragraph.
The base is trying to represent the outdoor temperature at which the house no longer needs heat, because the sun, the people, and the appliances cover the loss. Older leaky houses often line up near 65. A tight house kept at 68, with ordinary internal gains, may be closer to a base of 60 or even lower. If your lookup tool offers both, run the page twice. The rank order of projects rarely flips. The annual total does move.
From a cold-night rate to a year
The heat-loss sketch gives BTU per hour at one temperature difference. Divide that rate by the temperature difference and you have BTU per hour per degree, sometimes called a UA. Multiply by 24 hours and by the degree days.
Yearly heat, in BTU, is about that UA times 24 times the heating degree days.
This assumes the loss is proportional to the temperature difference, which conduction and a simple infiltration estimate are. It ignores the sun through south glass, which is heat you gained, and it ignores people and appliances. The number comes out high for a real occupied house. Use it to compare an insulation job with a collector, not to promise a fuel delivery.
Then divide by the heating equipment. A 90 percent furnace needs more fuel BTU than the heat delivered. A heat pump needs less electricity than a resistance heater for the same heat, by about its coefficient of performance. The calculator below stops at the heat. The note under the result is where the equipment belongs.
Using the number without fooling yourself
Compare two winters by their degree days before you praise a project. If this winter had 20 percent more degree days, a bill that only rose 10 percent may mean the work helped. A bill that fell in a warm winter may mean the weather helped. Divide fuel use by degree days and look at that ratio across years. It is a better scoreboard than the dollar total.
Do not use a degree-day total to size a furnace to the last thousand BTU. Design-night temperature does that job, and a safety margin belongs to the installer. Degree days are an energy total, not a peak.
Look up the local number
Write the town, the year or the climate normal, and the base temperature on the same line.
Bring a heat-loss rate
From the sketch, with the temperature difference you used. Divide to get BTU per hour per degree.
Multiply by 24 and by the degree days
That is the high estimate of annual heat. Run the calculator so the arithmetic is not the interesting part.
Apply the equipment you have
Furnace efficiency or heat-pump COP. Then compare with the space-heat remainder on the bills. If they are wildly different, believe the bills and revisit the sketch.
Further reading
These links go to outside sources. This book cites them by link and does not copy their words or pictures.
- https://www.builditsolar.com/Projects/Conservation/conservation.htm
- https://www.builditsolar.com/Projects/Conservation/BlowerDoor/BlowerDoor.htm
- https://www.builditsolar.com/Projects/Conservation/BlowerDoor/BuildingBlowerDoor.htm
- https://www.builditsolar.com/References/Calculators/HeatLoss/HeatLoss.htm
- https://www.builditsolar.com/Experimental/IRCamera/IRCamera.htm
General education, not a permit or a stamped design. Follow the safety note in the guide, read the safety disclaimer, and hire a licensed trade when the work requires one.